ماژول نمایشگر و اندازه گیری ولتاژ و جریان (غیر مستقل) با ارتباط RS485 پروتکل Modbus YLF-BT-0082 DC dual-display voltage Current liquid crystal head RS485 supports the Modbus protocol

نمایشگر و ماژول کنترل ولتاژ و جریان الکتریکی تا 30 ولت و 3 آمپر قابل اتصال به کامپیوتر و انواع میکروکنترلرها جهت دریافت و ذخیره و تحلیل داده های ولتاژ و جریان

  • مدل YLF-BT-0082
  • ابعاد 47.8 * 28.8 * 30mm
  • سایر ویژگی ها رنج دما: -10 تا 100
  • سایر ویژگی ها ارتباط سریال RS485

فروشنده:‌ فروشگاه اینترنتی پارتینه


آماده ارسال از انبار پارتینه


شناسه محصول: 72755


132,000 تومان

مشخصات ماژول نمایشگر و اندازه گیری ولتاژ و جریان (غیر مستقل) با ارتباط RS485 پروتکل Modbus

Description:
A DC Ammeter is a device to measure DC current.
It measures the current by measuring the voltage across a shunt resistance that is passing the measured current. So the voltage across this shunt resistance is linearly proportional to the measured current. This voltage proportional to the current is then converted to a digit numerical value by means of Analog to Digital Converter (ADC).It includes Screen display voltage and current with a MODBUS protocol functions. It can be used with PC, PLC communication equipment for data collection.

Product Features:
Voltage: none- independent power supply can be measured 5~30V
Current: 0 ~ 3A
Temperature: -20 ~ 100 degrees
Accuracy: 1% ( ± 1 word, the greater the voltage and current range, accuracy reduced accordingly )
supports standard Modbus RTU protocol, communication RS485
Single voltage measurement, current and temperature measurement all the way (fever due to the first table, there is resistance default temperature distribution, but not welded, self-extended, can improve the measurement accuracy)
Automatic Voltage and temperature switch display, the current separate row (display mode can be set via button Temperature: In case of power failure, press and hold the button is not loose, electricity, three seconds after release the button, you can switch back on the power mode)
Protocol functions can be set with device addresses 1~255, through the PC software settings;

Interface Description:
Left side pin A, B-side for the RS485 interface for Modbus communication
lower side GND voltage is negative, IIN measurable current use, the VCC when independent power supply module for the power supply positive, the non-independent power supply voltage for the positive test, the VIN independent power supply voltage is positive.

Software settings:
In the "Communication Settings" set the serial number, open the serial port.
In the "Analog capture" item set module address ( default address is "1", in the case of unknown module address, you can "change the module address" item of the module address changes )
In the "Analog capture" click "acquisition" command on it.
As a "communication error" to confirm RS485 interfaces A, B whether the reverse side.

Calibration method:
Connect precise 12V (100V independent power supply for 30V) when the power is short-circuited temperature-sensitive resistor for 5 seconds, the screen will blackout, disconnect the power to connect the calibration Well, pay attention to 12V power supply must be accurate, otherwise calibrated also not allowed.